FTTH Drop Cable Selection: GJXH, GJXFH, GJYXCH and GJYXFCH

Highjoule 2026-10-10

Choose an FTTH drop cable by its route and support method first. For supported indoor runs, compare GJXH with steel strength members and GJXFH with FRP strength members. For aerial drops that need an integral messenger, compare GJYXCH and GJYXFCH. Then match the jacket, fiber and mechanical ratings to the installation.

The important distinction is not simply “indoor versus outdoor.” A cable fixed along an exterior wall still needs outdoor suitability, even when it does not need a messenger. Likewise, FRP side strength members do not make a cable all-dielectric if it also contains a steel messenger.

How to Choose an FTTH Drop Cable

Quick selection: compare the four constructions

The table compares the constructions described on Highjoule’s four product pages. FRP means fiber-reinforced polymer. The dimensions shown apply to the listed configurations with four fibers or fewer, rather than every cable sold under these model names.

Model Side strength members Integral messenger Published profile Selection starting point
GJXH drop cable Two phosphated steel wires None 2.0 × 3.0 mm Supported indoor route where metallic members are acceptable
GJXFH drop cable Two FRP members None 2.0 × 3.0 mm Supported indoor route requiring non-metallic reinforcement
GJYXCH self-supporting drop cable Two phosphated steel wires Steel wire 2.0 × 5.0 mm Self-supporting route where steel side members and a steel messenger are acceptable
GJYXFCH self-supporting drop cable Two FRP members Steel wire 2.0 × 5.0 mm Self-supporting route requiring FRP side members but allowing a steel messenger

Use this table to narrow the construction, not to approve a route. Outdoor exposure, building fire requirements and aerial loading remain separate checks.

GJXH vs GJXFH: steel or FRP for supported indoor runs?

Both designs place the optical fiber between two parallel strength members in a compact, flat jacket. The principal difference is the material of those members: steel in GJXH and FRP in GJXFH.

Choose GJXH when the building specification permits metallic reinforcement and the cable meets the required installation loads, bend limits and fire performance. Choose GJXFH when the specification calls for non-metallic reinforcement or an all-dielectric cable construction. For an all-dielectric requirement, the approved construction must contain no metallic components anywhere in the cable.

Do not assume that steel automatically gives the finished cable a higher tensile rating. Highjoule’s listed GJXH and GJXFH configurations both specify 100 N long-term and 200 N short-term allowable tensile load. For these configurations, reinforcement material alone does not establish a performance advantage.

When both meet the project specification, compare the actual quotation and handling requirements. A protected indoor route does not need an integral messenger merely because a self-supporting cable is also available.

Indoor FTTH Drop Cable with FRP Strength Members

GJYXCH vs GJYXFCH: compare the cable body and messenger separately

Both self-supporting designs add a steel messenger alongside the fiber-carrying body. GJYXCH uses steel side strength members; GJYXFCH uses FRP side members. The messenger provides the additional supporting element for the span.

Choose GJYXCH when steel is acceptable in both positions. Choose GJYXFCH when the specification requires FRP beside the fiber but permits a steel messenger. Neither selection, by itself, establishes an allowable span or proves that the jacket suits every outdoor environment.

All-dielectric construction and lightning exposure

The GJYXFCH construction compared here is not all-dielectric: its side members are non-metallic, but its messenger is steel. Where metal is prohibited throughout an aerial cable, specify an appropriate all-dielectric self-supporting construction instead.

Optical transmission is not the same issue as electrical conductivity in cable components. The FOA cable reference distinguishes optical fiber’s immunity to electromagnetic fields from the grounding and bonding considerations associated with metallic cable elements.

An all-dielectric construction avoids a continuous metallic path through the cable; it is not a blanket “lightning-proof” guarantee. For routes near power infrastructure or exposed to lightning, the project design must address cable construction, separation, attachments and any required bonding. Selecting FRP alone does not approve the route.

Match the jacket and fiber to the installation

Indoor, outdoor and mixed routes

The four linked Highjoule descriptions specify an LSZH flame-retardant jacket. LSZH means low-smoke zero-halogen, but the material description does not replace a finished-cable fire classification or outdoor qualification.

For an indoor route, identify the building space and the required fire performance. Riser and air-handling spaces, for example, can call for different cable ratings. Corning’s indoor cable guidance explains why jacket selection must follow the application and local requirements, rather than an LSZH label alone.

For exposed outdoor sections, specify sunlight and moisture exposure, installation and operating temperatures, and any relevant water-blocking requirement. A black jacket or a self-supporting profile is not, by itself, evidence that those requirements are met. An underground duct also needs assessment for moisture and pulling conditions; it is not an indoor environment simply because the cable is enclosed.

For a continuous outdoor-to-indoor run, select a construction accepted for both sections or plan a suitable transition at the building entry.

G.657 fiber and finished-cable bend limits

Bend-insensitive single-mode fiber is useful where drop routes include compact termination boxes and restricted routing space. ITU-T G.657 addresses improved bending performance for these applications. State the exact required category, such as G.657.A1 or G.657.A2, rather than ordering only “G.657 fiber.”

G.657.A2 provides stronger bending performance than A1 under its specified test conditions, but fiber-level performance is not permission to bend the finished cable to the same radius. Select the category against the operator specification and route, then check the cable’s own handling limits.

For a concrete example, Highjoule’s GJXFH table lists 15 mm static and 30 mm dynamic bend radius for its B6a configuration. Those are configuration-specific cable values, not a universal rule for every GJXFH or G.657 cable. For messenger-equipped cable, also establish whether the stated limit covers the complete assembly or the fiber-carrying body after messenger separation.

Read mechanical ratings before specifying an aerial span

Compare the same parameter under the same conditions. The following are published Highjoule values for the listed configurations with four fibers or fewer; they are not universal ratings attached to the model codes.

Model Long-term tensile load Short-term tensile load Long-term crush load Short-term crush load
GJXH 100 N 200 N 1,000 N/100 mm 2,200 N/100 mm
GJXFH 100 N 200 N 1,000 N/100 mm 2,200 N/100 mm
GJYXFCH 300 N 600 N 1,000 N/100 mm 2,200 N/100 mm

The distinction matters: 600 N short-term is not 600 N continuous working load. A crush rating expressed in N/100 mm describes a specified loading test; it is not an anchor or clamp rating. Obtain the applicable test conditions with the supply specification. GJYXCH needs its own configuration-specific mechanical data rather than values copied from GJYXFCH.

Why there is no single maximum span

An allowable span depends on cable and messenger properties, weight, sag, wind and ice loading, temperature, attachment points and the required clearances. The FOA aerial installation guide explains the relationship between loading, span, messenger selection and hardware.

A “self-supporting” label or a tensile figure in newtons cannot be converted directly into a maximum distance in meters. Provide the longest unsupported span and site conditions so the cable and supporting hardware can be assessed together.

Match clamps and termination hardware to the actual profile

Ask for the compatible clamp model, permitted cable dimensions, clamping location and applicable load rating. An S-type or wedge-clamp name alone does not establish compatibility. Follow the cable-and-hardware instructions rather than assuming every figure-8 clamp grips the same part of the cable.

At the subscriber end, check the entry size, strain relief, bend space and termination method. Pulling, stripping and messenger separation should follow the approved instructions without transferring installation loads to the optical fiber.

Messenger Clamp and FTTH Cable Entry Detail

Three route examples: turn the comparison into a selection

These are illustrative procurement scenarios, not project records or approved installation designs.

Supported indoor apartment connection

Assume the drop runs through protected indoor conduit from a floor distribution box to an apartment, with no open aerial span.

Start with GJXH or GJXFH rather than a messenger-equipped model. If the building specification prohibits metallic cable components, shortlist a verified all-dielectric GJXFH construction. If it permits metal, either design remains a candidate. The remaining selection turns on the required fire performance, fiber category, pulling conditions and space available at the entry and termination box.

Pole-to-house drop with an indoor continuation

Assume the route has a 40 m aerial span followed by 15 m indoors. Tell the supplier both dimensions, not merely “55 m of drop cable.” The 40 m span drives the aerial assessment; the indoor section drives the building-entry and fire-performance decision. These route dimensions are not the final cable cut length, which must also accommodate the designed sag, termination allowance and slack.

Shortlist GJYXCH or GJYXFCH according to the side-member requirement and whether a steel messenger is permitted. Then obtain the applicable span-and-hardware assessment and decide whether to use one appropriately qualified cable or transition at the entry. Neither model is approved for this example solely because the span is 40 m.

Exterior wall routing followed by an indoor riser

Assume the cable is supported along an exposed façade before entering a building, with no free span.

The route does not automatically require an integral messenger, but it does require a cable suitable for the outdoor exposure and the indoor space. Specify those environments first, then evaluate an appropriately qualified supported drop construction or a transition arrangement. Do not select an indoor-only cable just because the exterior section is fixed to a wall.

Compare quotations on the same supply specification

A model code and a price per meter are not enough to compare offers. Ask suppliers to quote the same fiber category, fiber count, reinforcement, messenger, jacket performance and mechanical requirements. Also align the termination method, cut lengths, packaging and supporting hardware.

Keep cable cost and installation scope separate. A quote for bare cable is not equivalent to one that includes pre-termination, clamps or project-specific documentation. Compare the compliant supplied scope before deciding which offer costs less.

RFQ item What to state
Project and route Country, operator or building requirements, indoor/outdoor sections, support method and longest unsupported span
Construction Proposed model, steel or FRP side members, messenger requirement, and whether metal is prohibited anywhere in the cable
Fiber Fiber count, exact fiber category and optical acceptance requirements
Jacket and environment Jacket material and color, required fire performance, sunlight and moisture exposure, and temperature conditions
Mechanical and hardware requirements Dimensions and tolerances, long-/short-term tensile and crush limits, installation/service bend limits, and compatible clamps and entries
Delivery and documentation Quantity, cut or reel lengths, packaging, bare or pre-terminated supply, approved drawing, datasheet revision and required reports

For example, an initial indoor enquiry could read:

Please quote a two-fiber GJXFH drop cable for a supported indoor route. We require FRP side strength members, no metallic cable components, no messenger, G.657.A2 fiber and an LSZH jacket meeting the attached building fire-performance requirement. Please state the proposed dimensions, installation and service bend limits, tensile and crush ratings, reel options and datasheet revision.

This is an example of a buyer’s requested specification, not confirmation that every item is standard stock. Attach the relevant project requirements and have the supplier identify any proposed deviation.

Frequently asked questions

Can GJXH be used in an outdoor conduit?

Only when the exact cable is qualified for the conditions in that route. Conduit does not automatically eliminate moisture, temperature exposure or pulling loads. An indoor-only GJXH specification is therefore insufficient; request the appropriate environmental and mechanical qualification.

Can a self-supporting drop cable continue indoors after its messenger is removed?

Only where the remaining cable construction and the separation method are approved for that use. Removing the messenger does not change the jacket’s fire classification. The indoor section must still meet the building requirements and the applicable cable bend limits.

Request an FTTH drop cable recommendation

Send Highjoule your project country, route sketch, fiber count and longest unsupported span. Include any restriction on metallic components and the required jacket performance. Request a model recommendation and quotation with the matching construction drawing and configuration-specific datasheet.

The useful outcome is not just a model name: it is a cable construction, installation method and documented specification that match the route from the distribution point to the subscriber.