HR1000 Cabinet Level Micro Module Data Center

HR1000 Cabinet Level Micro Module Data Center

The J-net Rack HR1000 is a next-generation smart micro-module data center solution that integrates power distribution, UPS, monitoring, cooling, fire protection, lighting and cabinet systems. Provide an unprecedented excellent working environment and reliable guarantee platform for small and micro IT room Application Scenarios.
Product Features
In-depth integration of data center infrastructure products in one cabinet, on-site installation is simply fixed, powered on, and construction time is only 4 hours;
A single system is configured with a color touch screen, which can display all system parameters, monitoring information, alarm records, etc. locally;
Network monitoring management, which can be connected to a third-party monitoring system to achieve unattended management of remote browsing monitoring;
Rack-mounted air-conditioning system, saving air-conditioning cabinet installation space;
Frequency conversion refrigeration technology, cold and hot channel isolation, PUE as low as 1.5;
The welded frame can meet the requirements of a magnitude 9 earthquake;
Compatible with dehumidification heating function to avoid the risk of condensation;
Real-time monitoring of internal resistance, voltage and temperature of the battery, intelligent disconnection of overheating to prevent fire;
Optional cabinet-level fire extinguishers to meet fire protection needs;
Contact Us

Product Parameters

Single cabinet configuration table
Cabinet system
Dimensions (H x W x D MM) 2000(2200)X 600X 1350
Capacity 42U(46U)
Protection Rating IP30
Operating Temperature -20℃~45℃
Installation Concrete floor, raised floor
Maximum load per cabinet 6KW
IT cabinet bearing requirements Static load 1500kg, dynamic load 1000kg
Cooling Generating Systems
Rated AC input power supply 220V AC 50Hz
Cooling capacity (L35/L35) 3.5KW
Rated Input Power 1270W
Rated current 8A
Heating Capacity 1000W
Refrigerant R410A
Sensitivity to heat ratio ≥0.99
Energy Efficiency Ratio ≥3.2
Air distribution Front air supply, rear air return
Installation Rack mounting
• Distribution System
Lightning protection level Class C, In 20ka, Imax40ka
Power Input Single and dual channels optional
Dual Power Switching System Optional for 2-way input
UPS Capacity 6KVA / 10KVA
UPS Architecture N、N+1、2N
Input Voltage 220V Single Phase 380V Three Phase
Output voltage 220V~240V AC 50Hz
380V~400V AC 50Hz
Output power factor 0.9
Battery Configuration Rack-mounted lithium batteries, lithium battery cabinets
Backup time 15~30min
Repair bypass Standard
Monitoring system
Monitoring system Support remote web interface access
Local Interface Standard 10-inch touch screen
Mobile O&M Mobile App, SMS Alerts
Smoke detector Optional
Water immersion Optional
Temperature and humidity Optional
door-lock Optional
Video monitoring Optional
Multi-cabinet configuration table
Cabinet system Cooling Generating Systems
Dimensions (H x W x D MM) 2000(2200)X 600X 1350 Rated AC input power supply 220V AC 50Hz
Piping Type Multiple cabinets Cooling capacity (L35/L35) 3.5KW*2
Number of single cabinets 2-3 units Rated Input Power 1270W*2
Capacity 42U (46U) * number of cabinets Rated current 8A
Protection Rating IP30 Heating Capacity 1000W*2
Operating Temperature -20℃~45℃ Refrigerant R410A
Installation Concrete floor, raised floor Sensitivity to heat ratio ≥0.99
Maximum load per cabinet 6KW Energy Efficiency Ratio ≥3.2
Supports maximum power consumption of IT load 10KW Air distribution Front air supply, rear air return
IT cabinet bearing requirements Static load 1500kg, dynamic load 1000kg Installation Rack mounting
• Distribution System Monitoring system
Lightning protection level Class C, In 20ka, Imax40ka Monitoring system Support remote web interface access
Power Input Single and dual channels optional Local Interface Standard 10-inch touch screen
Dual Power Switching System Optional for 2-way input Mobile O&M Mobile App, SMS Alerts
UPS Capacity 10KVA Smoke detector Optional
UPS Architecture N、N+1、2N Water immersion Optional
Input Voltage 220V Single Phase 380V Three Phase Temperature and humidity Optional
Output voltage 220V~240V AC 50Hz
380V~400V AC 50Hz
door-lock Optional
Output power factor 0.9 Video monitoring Optional
Backup time 15~30min Fire Fighting System
Repair bypass Standard Rack fire extinguishers Temperature detection and fire extinguishing all-in-one machine