High power micro inverter, output power up to 2000VA.
Component-level MPPT and data monitoring, higher power generation and simpler operation and maintenance.
With reactive power compensation function, in line with NB/T 32004-2018 standard.
Meets the most stringent North American fast shutdown requirements, safer to be applied to rooftop power stations.
Model Number | HJ-MG0003-W (500W) |
Input (DC) | |
Suitable Array Power (W) | 360~600+ |
Max Input Voltage (V) | 65 |
MPPT Voltage Range (V) | 16*60 |
Start-up Voltage (V) | 22 |
Max Input Current (A) | 15 |
Max Input Short-Circuit Current (A) | 25 |
Number of MPPTs | 1 |
Max Input Route per MPPT | 1 |
Output (AC) | |
Rated Output Power (VA) | 450 |
Rated Output Current (A) | 2.05 |
Output Voltage Range (V) | 220/180*275 |
Rated Frequency Range (Hz) | 50/45*55 |
Adjustable Power Factor (Rated Power) | >0.99 Default 0.8 ahead…0.8 behind |
Total Harmonic Distortion (Rated Power) | <3% |
Max Number of Strings per Phase (2.5mm² Total) | 11 |
Max Number of Strings per Phase (4mm² Total) | 15 |
Max Number of Strings per Phase (6mm² Total) | 19 |
Efficiency | |
Peak Efficiency | 96.6% |
MPPT Efficiency | 99.8% |
Night Loss (mW) | <50 |
Mechanical Parameters | |
Operating Temperature (℃) | -40*+65 |
Dimensions (W×H×D mm) | 182×164×30 |
Weight (kg) | 1.75 |
Protection Level | Outdoor-IP67 |
Cooling Method | Natural convection |
Safety and Protection Features | |
Anti-island Protection, Input Anti-reverse Protection, Output Short-Circuit Protection, Output Overcurrent Protection, Output Overvoltage Protection, 6000V Surge Protection | |
Features | |
Active Power Regulation, Reactive Power Regulation, High Voltage Ride Through (optional), Low Voltage Ride Through (optional), High Frequency Transformer Isolation | |
Others | |
Communication Method | Sub-1G |
Model Number | HJ-MG0003-W (1000W) |
Input (DC) | |
Suitable Array Power (W) | 400*670+ |
Max Input Voltage (V) | 65 |
MPPT Voltage Range (V) | 16*60 |
Start-up Voltage (V) | 22 |
Max Input Current (A) | 2×15 |
Max Input Short-Circuit Current (A) | 2×25 |
Number of MPPTs | 2 |
Max Input Route per MPPT | 1 |
Output (AC) | |
Rated Output Power (VA) | 900 |
Rated Output Current (A) | 4.09 |
Output Voltage Range (V) | 220/180*275 |
Rated Frequency Range (Hz) | 50/45*55 |
Adjustable Power Factor (Rated Power) | >0.99 Default 0.8 ahead…0.8 behind |
Total Harmonic Distortion (Rated Power) | <3% |
Max Number of Strings per Phase (2.5mm² Total) | 5 |
Max Number of Strings per Phase (4mm² Total) | 7 |
Max Number of Strings per Phase (6mm² Total) | 9 |
Efficiency | |
Peak Efficiency | 96.50% |
MPPT Efficiency | 99.80% |
Night Loss (mW) | <50 |
Mechanical Parameters | |
Operating Temperature (℃) | -40*+65 |
Dimensions (W×H×D mm) | 261×180×35.1 |
Weight (kg) | 3.2 |
Protection Level | Outdoor-IP67 |
Cooling Method | Natural convection |
Safety and Protection Features | |
Anti-island Protection, Input Anti-reverse Protection, Output Short-Circuit Protection, Output Overcurrent Protection, Output Overvoltage Protection, 6000V Surge Protection | |
Features | |
Active Power Regulation, Reactive Power Regulation, High Voltage Ride Through (optional), Low Voltage Ride Through (optional), High Frequency Transformer Isolation | |
Others | |
Communication Method | Sub-1G |
Isolation Method | High Frequency Transformer Isolation |
Grid Connection Standard | NB/T 32004-2018 |
Model Number | HJ-MG0003-W (2000W) |
Input (DC) | |
Suitable Array Power (W) | 400~670+ |
Max Input Voltage (V) | 65 |
MPPT Voltage Range (V) | 16~60 |
Start-up Voltage (V) | 22 |
Max Input Current (A) | 4×16 |
Max Input Short-Circuit Current (A) | 4×25 |
Number of MPPTs | 4 |
Max Input Route per MPPT | 1 |
Output (AC) | |
Rated Output Power (VA) | 2000 |
Rated Output Current (A) | 9.09 |
Output Voltage Range (V) | 220/180*275 |
Rated Frequency Range (Hz) | 50/45*55 |
Adjustable Power Factor (Rated Power) | >0.99 Default |
Total Harmonic Distortion (Rated Power) | <3% |
Max Number of Strings per Phase (2.5mm² Total) | 2 |
Max Number of Strings per Phase (4mm² Total) | 3 |
Max Number of Strings per Phase (6mm² Total) | 4 |
Efficiency | |
Peak Efficiency | 96.50% |
MPPT Efficiency | 99.80% |
Night Loss (mW) | <50 |
Mechanical Parameters | |
Operating Temperature (℃) | -40*+65 |
Dimensions (W×H×D mm) | 331×218×40.6 |
Weight (kg) | 5.56 |
Protection Level | Outdoor-IP67 |
Cooling Method | Natural convection |
Safety and Protection Features | |
Anti-island Protection, Input Anti-reverse Protection, Output Short-Circuit Protection, Output Overcurrent Protection, Output Overvoltage Protection, 6000V Surge Protection | |
Features | |
Active Power Regulation, Reactive Power Regulation, High Voltage Ride Through (optional), Low Voltage Ride Through (optional), High Frequency Transformer Isolation | |
Others | |
Communication Method | Sub-1G |
Isolation Method | High Frequency Transformer Isolation |
Grid Connection Standard | NB/T 32004-2018 |
Note: Specifications are subject to change without prior notice for product improvement. Data Sheet / Get your free product catalog and the latest pricing!
The HJ-MG0003-W micro inverter includes reactive power compensation functionality, which helps maintain grid stability in areas like California where there is a high concentration of solar installations. This feature aligns with the NB/T 32004-2018 standard, ensuring compatibility and reliability.
The HJ-MG0003-W micro inverter is ideal for rooftop power stations and balcony photovoltaic installations in European homes. It provides efficient power conversion and monitoring, making it a perfect choice for maximizing solar energy utilization in residential settings.
The above answer is for reference. For further details, please reach out to us.
* Fill out this form and our experts will help you find the perfect solar storage solution for your home or business.
* Fill out this form and our experts will help you find the perfect solar storage solution for your home or business.